Product
Features:
VENTAS Air Handling Units are produced with an air
flow range of 1000m3/h to 100000m3/h.
Air Handling Units for Hygienic Applications (HY-AHU)
Internal surfaces of hygenic
air handling units is coated with stainless steel sheet. anti-bacterial
silicone is applied to the bottom surface for water imperviousness. Base height
is designed to cover all type of the syphon conditions.
In hygenic air handling
units, coils are manufactured as epoxy coated and with copper header. Coil’s
case and sled systems are made out of stainless steel sheet.
In order to prevent
water accumulation at cell’s connection areas, the units are connected with
special connectors and then coated with stainless steel sheet such that a flat
surface is obtained. In order to enable any kind of washing within the units
and prevent any water accumulation and air leakage, special discharging system
with siphon is employed in production by default. Moreover, for directly
monitoring and controlling the inside of air handling unit during operation,
there are placed several monitoring windows, waterproof and airproof lightings.
In order to meet the
requirements from fans during process correctly, fans are chosen to be backward
inclined with seldom wings and such that they can be easily disinfected. Plug
fan applications are preffered more often since it enables air flow
measurements and accurate setting.
Panels and Outer Cage
System
For application areas such as hospitals (operation and clean room), pharmaceuticals factories, chemical production plants, food production factories, VENTAS Hygienic Air Handling Units are offered.
For panel production material, VENTAS provides
galvanized, rustproof, aluminium and PVC coated sheet options. Moreover, the
color of Outer skin sheet metal of units is RAL 9002.
Special aluminium profiles are used at the outer cage
of air handling units. Profiles have a custom and closed design in order to
reduce the internal pressure losses as much as possible and prevent from
pollution that can be produced within the devices.
Corner and omega parts connecting outer cage system are designed
appropriate with the structure of profiles and strengtheners and manufactured
out of heat-resistant glass-strengthened composite material.
Panels are manufactured in sandwich structure with
double sides. Within panels, rock wool insulation material with 70kg/m3 density
is used as sound and heat insulation filling material. At connection
points of panels and outer cage, impermeable tight seals from RPDM material
with custom surface design, are used.
Within VENTAS Air Handling Units, air adjustment
dampers with aerodynamic type blades are
used which works with hidden geared impulsion system. Damper wings and frame
are manufactured from aluminium profile; moreover, gear system and bearing
systems are produced with a hard material resistant to heat, dust, and strong
against external hits. There are special air tight seals
between damper blades in order to guarantee air imperviousness.
Ventilator and Aspirator Units
VENTAS air handling unit's ventilator or aspirator
units are produced in standard chamber structure. While ventilator and aspirators
can be chosen as forward or backward curved blades, radial single/double suction fans balanced statically and/or dynamically, they can also
be designed with plug-fan. Electrical motor of fans are montaged on to the same
chassis. In order to prevent the vibration that can be occured especially
within this chamber, to the other part of the air handling unit, rubber or
spring type vibration isolator is used at an amount and size dependent on the
capacity, size, fan and motor cycles of the unit.
Belt and Pulleys
Pulleys used in fans and motors are V-belt pulleys appropriate to DIN
2211 and TS 148 norms. Pulleys are formed in two parts. Since, after the first
part is mounted in fabric to the fan and motor spindle, the second part can be
mounted without a need for a hardware, pulley size can be made very easily upon
need.
In order to transfer power between motor and fan pulleys, narrow V-belts
(appropriate to TS 198/40 DIN 7753/1) or classical V-belts (appropriate to TS
198/1 DIN 2215) are used. Moreover, there is a belt stretching mechanism for
adjusting the belt tightness between the fan and motor to the desired and
efficient level.
Filters
Montage frames are designed for different filter classes used together
with air handling units for several different purposes. Thanks to this design,
filters can be placed very easily into their sockets with spring systems.
Moreover, with this design, any possible by-pass that can be occured at filters
are reduced to minimal levels. G3-G4 class filters used as front-side filters,
have galvanized frames, and with galvanized string connections, they are installed with increased
resistance to air flow.
Bag filters with different classes are used as second-level filters in
air handling units. Besides, they are used as first-level filters for hygienic
air handling units. Bag filters can be chosen out of F5 to F9 classes. In air
handling units, rigid filters can be used as the last filter at between classes
F5 to F9 upon need. In order to filter undesired odor, active carbon filters
both with carbon panels or with cartridge, can be used.
Coils
All coils are subject to
hydrostatic tests before installation. In order for easy maintenance and
montaging, special sliding mechanism is designed. In air handling units with
cooling coils, rustproof condensation pan and polypropylene drop holder
(appropriate to DIN 7728 standards and resistant up to 130oC) is
used in standard.