Product Features:
VENTAS
Air Handling Units are produced with an air flow range of 1000m3/h to 100000m3/h.
Pool Dehumidification
Air Handling Units
Pool
dehumidification units provide optimal solution for air-conditining control in
indoor swimming pools, SPA and similar health and wellness areas.
Pool dehumidification units can
be produced in different capacities such that they can serve a wide range of
application areas from a small villas to an olympic swimming pool.
Pool dehumidification units are
designed in order to solve the humidity problem in the targeted
air-conditioning area with a energy-efficient way.
These
units are served with an automation system and direct expansion cooling
circuit. All cooling circuit and automation device parts are
integrated to the air handling device such that humidifying and
air-conditioning process work with in the unit.
Panels and Outer Cage
System
Standard KS Series Air Handling Units
are manufactured in three different panel thickness of 28mm, 43mm and 63mm.
For application areas such as hospitals
(operation and clean room), pharmaceuticals factories, chemical production
plants, food production factories, VENTAS Hygienic Air Handling Units are
offered in two different panel thicknesses of 43mm and 63mm.
Within all air handling units filling
materials such as rock wool, glass wool, polyurethane can be used upon request.
Sheet metal thickness between 0,80mm and
1,2mm is available for alternative air handling units. For panel production
material, VENTAS provides galvanized, rustproof, aluminium and PVC coated sheet
options. Moreover, the color of Outer skin sheet metal of units is RAL 9002.
EUROVENT Certified VKS Series of Air
Handling Units have 63mm sandwich panels with an outer skin of 0,8mm painted
Galvanized Sheet metal and 1mm Galvanized sheet metal inside.
Special aluminium profiles are used at the outer cage of air handling
units. Profiles have a custom and closed design in order to reduce the internal
pressure losses as much as possible and prevent from pollution that can be
produced within the devices.
Corner and omega parts connecting outer cage system are designed
appropriate with the structure of profiles and strengtheners and manufactured
out of heat-resistant glass-strengthened composite material.
Panels are manufactured in sandwich structure with
double sides. Within panels, rock wool insulation material with 70kg/m3 density
is used as sound and heat insulation filling material. Glass wool and
polyurethane isolation materials are also available upon request. At connection
points of panels and outer cage, impermeable tight seals from RPDM material
with custom surface design, are used.
Within VENTAS Air Handling Units, air adjustment
dampers with aerodynamic type blades are
used which works with hidden geared impulsion system. Damper wings and frame
are manufactured from aluminium profile; moreover, gear system and bearing
systems are produced with a hard material resistant to heat, dust, and strong
against external hits. There are special air tight seals
between damper blades in order to guarantee air imperviousness.
Ventilator and Aspirator Units
VENTAS air handling unit's ventilator or aspirator units
are produced in standard chamber structure. While ventilator and aspirators can
be chosen as forward or backward curved blades, radial single/double suction fans balanced statically and/or dynamically, they can also
be designed with plug-fan. Electrical motor of fans are montaged on to the same
chassis. In order to prevent the vibration that can be occured especially
within this chamber, to the other part of the air handling unit, rubber or
spring type vibration isolator is used at an amount and size dependent on the
capacity, size, fan and motor cycles of the unit.
Belt and Pulleys
Pulleys used in fans and motors are V-belt pulleys appropriate to DIN
2211 and TS 148 norms. Pulleys are formed in two parts. Since, after the first
part is mounted in fabric to the fan and motor spindle, the second part can be
mounted without a need for a hardware, pulley size can be made very easily upon
need.
In order to transfer power between motor and fan pulleys, narrow V-belts
(appropriate to TS 198/40 DIN 7753/1) or classical V-belts (appropriate to TS
198/1 DIN 2215) are used. Moreover, there is a belt stretching mechanism for
adjusting the belt tightness between the fan and motor to the desired and
efficient level.
Filters
Montage frames are designed for different filter classes used together
with air handling units for several different purposes. Thanks to this design,
filters can be placed very easily into their sockets with spring systems.
Moreover, with this design, any possible by-pass that can be occured at filters
are reduced to minimal levels. G3-G4 class filters used as front-side filters,
have galvanized frames, and with galvanized string connections, they are installed with increased
resistance to air flow.
Bag filters with different classes are used as second-level filters in
air handling units. Besides, they are used as first-level filters for hygienic
air handling units. Bag filters can be chosen out of F5 to F9 classes. In air
handling units, rigid filters can be used as the last filter at between classes
F5 to F9 upon need. In order to filter undesired odor, active carbon filters
both with carbon imbued panel or with cartridge, can be used.
Coils
All coils are subject to
hydrostatic tests before installation. In order for easy maintenance and
montaging, special sliding mechanism is designed. In air handling units with
cooling coils, rustproof condensation pan and polypropylene drop holder
(appropriate to DIN 7728 standards and resistant up to 130oC) is used in
standard.
Humidifier
Silencer
Please have a look on product catalogs for technical details ...